Oil and gas pipelines use pigs (Pipeline Inspection Gauges) to clean or inspect the line. During pig firing (launch/receive) the launcher holds pressurized hydrocarbon and generates metallic friction sparks. A reported incident involved ignition while opening a pig receiver.
Pig Types
- Cleaning pig: removes solid paraffin with scraper cups
- Gauge pig: detects geometric anomalies
- Smart pig: MFL/ultrasonic corrosion mapping
- Sphere (top): liquid separation, gas line condensate
Launcher/Receiver Safety
- Isolation valve: double block + bleed
- Venting: safe location, flare or atmosphere
- Purge: N2 or methanol before launch
- Pressure gauge: verify 0 psi before opening
- Earthing: launcher body grounded - dissipate static
Metallic Spark Risk
- Pig metal part: worn scraper cups create friction sparks
- Iron sulfide (FeS): pyrophoric - ignites in air
- Iron sulfide control: per the NFPA 69 annex, deposits are kept wet or the vessel is kept inert; iron sulfide can ignite if air enters (NFPA 69, A.7.2.4.4)
- MIE methane: 0.24 mJ - very low
- Solution: N2-purge with pig, fill receiver with N2 first
API 1130 and NFPA 30
- API 1130: pipeline leak detection - computational monitoring
- NFPA 30: piping systems that transfer flammable and combustible liquids (Chapter 27); transportation of liquids governed by US transport regulations is outside its scope (1.1.2)
- Area classification: the hazardous-area class and extent around a pig launcher or receiver is set site by site using the parameters of NFPA 497
- Foam monitor: deluge over launcher/receiver area
- PSSR: Pre-Startup Safety Review every pig campaign

MEP Calc — 110+ Engineering Calculators
MEP Calc bundles 110+ engineering modules in one iOS app: 21 fire calculations (sprinkler, fire pump, clean agent) plus heating, cooling, HVAC, plumbing, steam and natural gas. Download it on the App Store.
Download MEP Calc on the App Store
SprinkCalc — Fire Sprinkler Design Across Three Standards
SprinkCalc covers hazard classification, design density and area, K-factor selection, water demand and hydraulic calculations for NFPA 13, FM Global and BS EN 12845 in a single iOS app, and exports a professional PDF report. One of the few tools that unifies all three major fire protection standards.
Download SprinkCalc on the App StoreNFPA 30, API 1130, API RP 1165, ASME B31.4, B31.8, DOT 49 CFR Part 195. NFPA 30 Flammable Liquids standard.