FM Global DS 2-0: Automatic Sprinkler Installation Field Guide
Installation guidelines for automatic sprinklers under FM Global DS 2-0: FM Approved equipment, hazard classification HC-1 to HC-3, sprinkler spacing ...
FM Global Property Loss Prevention Data Sheets translated into field practice, with the differences from NFPA set out explicitly.
Installation guidelines for automatic sprinklers under FM Global DS 2-0: FM Approved equipment, hazard classification HC-1 to HC-3, sprinkler spacing ...
High-rise sprinkler design under FM Global DS 2-0: vertical zoning, static pressure limits, booster pump redundancy, pressure-reducing valves and inte...
Special sprinkler design for storage areas under FM Global DS 2-0: storage height, in-rack versus ceiling-only protection, integration with DS 8-9, an...
Pipe material selection, diameter, flow and velocity limits, hanger spacing tables, seismic bracing, where CPVC is accepted and grooved coupling pract...
Corrosion in automatic sprinkler systems under FM Global DS 2-1: microbiologically influenced corrosion, oxygen corrosion and galvanic attack, wet ver...
The FM Global DS 2-81 inspection, testing and maintenance regime for sprinklers, pumps, alarms and dry pipe valves: weekly, monthly, annual, three-yea...
Using the FM Global DS 2-89 pipe friction loss tables: the Hazen-Williams relationship, choosing the C coefficient for steel, cast iron, copper and CP...
Earthquake protection of water-based fire protection systems under FM Global DS 2-8: sway brace types and spacing, flexible couplings, seismic separat...
The hydraulic method behind sprinkler design under FM Global DS 3-0: the four governing relationships, K-factor and design density, building the deman...
Identifying and calculating the hydraulically most demanding sprinkler area under FM Global DS 3-0: selection criteria, step-by-step calculation, the ...
A field guide to pressure reducing and flow control valves under FM Global DS 3-11: PRV types, master versus zone arrangement, flow control valves, hi...
Sprinkler water demand for offices, hotels, hospitals, shopping centres and light manufacturing under FM Global DS 3-26: hazard class mapping, density...
Freeze protection for fire water tanks under FM Global DS 3-2: steam coils, electric immersion heaters, gas heaters, forced and gravity circulation, t...
Fire water tanks under FM Global DS 3-2: capacity calculation, selecting between steel, concrete and polyethylene, above and below ground options, fre...
FM Global DS 3-7 fire protection pumps in practice: pump room location and construction, alarms, suction and discharge piping rules, relief valves, pu...
Variable speed fire pump design under FM Global DS 3-7: energy saving, pressure control, comparison with the NFPA 20 approach, FM Approved package req...
BESS fire protection under FM Global DS 7-112 and DS 5-33: container design, mechanical ventilation, gas suppression, fire wall setback distances and ...
The formation stage, where cells are charged for the first time, carries the highest thermal runaway risk. FM Global DS 7-112 requires dedicated sprin...
Lithium-ion battery fire protection under FM Global DS 7-112: thermal runaway and reignition risk, sprinkler design by production stage, storage desig...
Chemical plant fire protection under FM Global DS 7-14: flammable liquid classification, sprinkler and foam-water design, ATEX zoning, explosion relie...
Industrial exhaust fire protection under FM Global DS 7-78: solvent, grease, dust and hot exhaust systems, duct velocity and material rules, in-duct s...
Commodity classification under FM Global DS 8-1: Class 1 to 4 definitions, expanded and unexpanded plastics, worked example lists, the effect of packa...
Mixed commodity storage under FM Global DS 8-1: the governing class rule, aisle separation, fire wall zoning and how the rules apply to e-commerce war...
Fire protection for ASRS under FM Global DS 8-34: mini-load, top-loading, vertically enclosed shuttle and crane-based systems, in-rack sprinkler arran...
Mini-load ASRS fire protection under FM Global DS 8-34: small tote systems at 4 to 12 m, typical e-commerce use, in-rack sprinklers every two to three...
Shuttle ASRS fire protection under FM Global DS 8-34: vertically enclosed structures, in-rack sprinklers at every level, robot emergency stop and bypa...
Fire protection rules for top-loading ASRS and classic crane-based AS/RS under FM Global DS 8-34: sprinkler arrangement, in-rack requirements and retr...
FM DS 8-9 in-rack sprinkler (IRAS) rules: when they are needed (Figure 3), 70 °C quick-response and minimum K115, face sprinklers within 450 mm,...
FM DS 8-9 (April 2026 revision) ceiling-level Storage sprinkler tables: the quick-response pendent K200, K240, K320 and K360 rows of Tables 7 and...
Plastics in FM DS 8-9: the four classes (cartoned/uncartoned × expanded/unexpanded), the 1.8 m scope threshold, ceiling designs in Tables 3-6 and...
The FM DS 8-9 (March 2010, April 2026 rev.) design flow: 3.0 / 1.8 m scope thresholds, eight commodity classes, single/double/multiple-row racks...