EN 12845 Articles

The European automatic sprinkler standard translated into field practice — hazard classes, design density, hydraulics, pumps and water supplies, storage, ESFR and CMSA, installation and maintenance.

Hazard ClassesHydraulicsPumpsStorageESFR & CMSAMaintenance
EN 12845

CMSA Design Criteria in Detail

CMSA design criteria: K-factor, pressure, 15-30 design sprinklers, commodity-to-listing matching and in-rack coordination in detail.

Fatih Selvi9 min
EN 12845

EN 12845 Alternate (Seasonal) Installations

EN 12845 alternate installations: the summer wet and winter dry cycle, the changeover procedure, the 25% enlarged design area and the field errors...

Fatih Selvi8 min
EN 12845

EN 12845 Annex E — High-Rise Requirements

EN 12845 Annex E high-rise sprinklers: pressure zones, standby pumps, twin risers, tank redundancy, intermediate tanks and high-rise design strategy.

Fatih Selvi9 min
EN 12845

EN 12845 Annex G — Idle Pallet Storage

EN 12845 Annex G idle timber and plastic pallet storage: stack heights, indoor and outdoor separation, sprinkler design density and distance rules.

Fatih Selvi8 min
EN 12845

EN 12845 Annex G — PP/PE Storage Bins

EN 12845 Annex G PP/PE storage bins: stack heights, ESFR, in-rack protection, molten drip risk and design criteria for plastic crates.

Fatih Selvi8 min
EN 12845

EN 12845 Annex H — System Monitoring

EN 12845 Annex H system monitoring: supervised valves, pressure, water level, pump controller signals, alarm panels and continuous supervision prin...

Fatih Selvi8 min
EN 12845

EN 12845 Annex J — Impairment Procedures

EN 12845 Annex J impairment management: planned and unplanned outages, tagging, fire watches, insurer notification and the restoration procedure.

Fatih Selvi8 min
EN 12845

EN 12845 Area of Operation: Shape and Location

EN 12845 area of operation shape: the 1.2 x root A rectangle rule, selecting the hydraulically most remote sprinkler group, and solving the narrow...

Fatih Selvi8 min
EN 12845

EN 12845 Beams, Ceilings and Sprinkler Layout

EN 12845 structural obstruction rules: deflector geometry under beams, the every-third-bay rule for narrow bays, roof truss flange clearances and s...

Fatih Selvi10 min
EN 12845

EN 12845 Block Plan, Signage and Marking Rules

EN 12845 block plan sign content, sprinkler valve marking, zone maps, fire service signs, spare sprinkler cabinets and correct signage on site.

Fatih Selvi7 min
EN 12845

EN 12845 Concealed Space Pipework and Sprinklers

EN 12845 sprinkler requirements in concealed spaces above ceilings, below raised floors and in roof voids: material class, airflow risk and testing...

Fatih Selvi8 min
EN 12845

EN 12845 Design Density and Area of Operation

EN 12845 design density (mm/min) and area of operation: reading the density-area tables, the 25% dry system increase and the basis of the hydraulic...

Fatih Selvi8 min
EN 12845

EN 12845 Diesel Engine Pump Sets

EN 12845 diesel pump sets: the 110% power margin, six hours of fuel, cooling, exhaust, the 15-second start rule and automatic starting, from field...

Fatih Selvi8 min
EN 12845

EN 12845 Diesel Pump Weekly Exercise Test

The EN 12845 weekly diesel pump routine: 20 minute run, automatic start and manual restart, oil, coolant and battery checks, log book content and c...

Fatih Selvi9 min
EN 12845

EN 12845 Drain, Test and Flushing Valves

EN 12845 drain valves, alarm and remote test valves, flushing connections and the annual zone test routine, with sizes, field errors and an NFPA 25...

Fatih Selvi8 min
EN 12845

EN 12845 Dry Pipe Installations

EN 12845 dry pipe sprinkler installations: air charging, water transit time (60/90 s), use in freezing areas, the 25% design area increase and comp...

Fatih Selvi8 min
EN 12845

EN 12845 Electric Sprinkler Pump Sets

EN 12845 electric pump sets: independent supplies, the 15 second rule, direct-on-line starting, HRC short-circuit protection with no overload, and...

Fatih Selvi10 min
EN 12845

EN 12845 Electrical Flow and Pressure Switches

EN 12845 electrical monitoring: flow and pressure switches, tamper switches, low level and temperature supervision, type A and B alarms and fire pa...

Fatih Selvi10 min
EN 12845

EN 12845 Fitting and Valve Pressure Losses

The EN 12845 equivalent length method: fitting and valve values, alarm valve and backflow additions, a worked example and the tee-counting error.

Fatih Selvi8 min
EN 12845

EN 12845 Frost Protection Strategies

EN 12845 freeze protection: dry systems, alternate wet and dry, glycol antifreeze, heat tracing and sprinkler design in freeze-prone areas.

Fatih Selvi8 min
EN 12845

EN 12845 HHP High Hazard Process Design

EN 12845 HHP classes: paint, plastic injection, rubber and timber processing. 7.5/10.0/12.5 mm/min over 260 m2, K115 selection, the HHP4 deluge exc...

Fatih Selvi8 min
EN 12845

EN 12845 HHS High Hazard Storage Design

EN 12845 high hazard storage: ST1-ST6 configurations, Category I-IV commodities, design density by height band and the 260-300 m2 area of operation.

Fatih Selvi9 min
EN 12845

EN 12845 In-Rack Sprinkler Layout by ST1-ST6

EN 12845 in-rack sprinkler layout across ST1-ST6 rack configurations: flue spacing, vertical intervals, K-factor, water shields and hydraulic desig...

Fatih Selvi9 min
EN 12845

EN 12845 Light Hazard (LH) Design

EN 12845 light hazard: 2.25 mm/min density over 84 m2, K57 sprinklers and wet pipe only. Pre-calculated design, a hydraulic example and the NFPA 13...

Fatih Selvi8 min
EN 12845

EN 12845 Maximum Sprinkler Coverage Area

EN 12845 coverage limits: LH 21 m2, OH 12 m2, HHP/HHS 9 m2, the separate sidewall table, reductions under obstructions and a worked example.

Fatih Selvi8 min
EN 12845

EN 12845 Minimum Distance Between Sprinklers

Why sprinklers closer than 2 m fail to operate: cold soldering, deflector-to-ceiling distance, and the rules for approaching walls, beams and canop...

Fatih Selvi8 min
EN 12845

EN 12845 Minimum Pipe Diameters

EN 12845 minimum DN values for fully calculated systems, the pre-calculated range and distribution sizes, and how steel grade and galvanising chang...

Fatih Selvi8 min
EN 12845

EN 12845 Minimum Sprinkler Discharge Pressure

EN 12845 minimum sprinkler discharge pressure: LH 0.7 bar, OH 0.35 bar, HHP/HHS 0.5 bar, absolute versus average minimum, in-rack 1-2 bar and the N...

Fatih Selvi8 min
EN 12845

EN 12845 Monthly Routine — Battery Checks

The EN 12845 monthly routine: diesel pump starter batteries, control panel cells, electrolyte specific gravity, replacement decisions and charger c...

Fatih Selvi7 min
EN 12845

EN 12845 Ordinary Hazard (OH1-OH4) Design

EN 12845 OH1 to OH4: the 5.0 mm/min density, 72-360 m2 areas of operation, the 25% dry system increase and the K80 minimum of 0.35 bar, with NFPA c...

Fatih Selvi8 min
EN 12845

EN 12845 Pipe Friction Loss: Hazen-Williams

The EN 12845 Hazen-Williams formula, C coefficients by material (mild steel 120, stainless 140, copper 140) and a DN50 worked example, plus the NFP...

Fatih Selvi8 min
EN 12845

EN 12845 Pipe Supports and Hanger Spacing

EN 12845 pipe support rules: 4 m for steel and 2 m for copper, the 50 percent exception, grooved joint rules, hanger load tables and the seismic gap.

Fatih Selvi9 min
EN 12845

EN 12845 Pre-Calculated Design for HHP and HHS

EN 12845 pre-calculated sizing for high hazard: K-factor limits, sprinkler count restrictions, the range and distribution tables, and the move to f...

Fatih Selvi8 min
EN 12845

EN 12845 Pre-Calculated LH Design

EN 12845 pre-calculated light hazard design: K57 sprinklers, the four-sprinkler rule, range pipe sizes, the 225 L/min pump duty and the most common...

Fatih Selvi8 min
EN 12845

EN 12845 Pre-Calculated OH Design

EN 12845 pre-calculated design for OH1-OH4: range and distribution pipe sizes, K80 sprinklers, the 0.35 bar minimum, wet versus dry, and pump flow.

Fatih Selvi8 min
EN 12845

EN 12845 Pressure Tanks

EN 12845 pressure tanks: limited to LH and OH1, the air-to-water ratio, the tank pressure formula, pressure equipment maintenance and why modern pr...

Fatih Selvi8 min
EN 12845

EN 12845 Pump Controllers and Monitoring

EN 12845 pump controllers: automatic start from two pressure switches, the manual-only stop rule, the mandatory alarm signals and BMS integration.

Fatih Selvi8 min
EN 12845

EN 12845 Pump Performance Characteristics

The EN 12845 pump pressure-flow curve: duty point, minimum pressure at 140% flow, closed valve pressure and the 12 bar limit, with field practice.

Fatih Selvi8 min
EN 12845

EN 12845 Quarterly and Half-Yearly Routines

EN 12845 quarterly (13 week) and half-yearly maintenance: hazard review, sprinkler cleaning, coatings, water supply testing, dry valve exercising a...

Fatih Selvi8 min
EN 12845

EN 12845 Reduced Capacity Tanks

EN 12845 reduced capacity sprinkler tanks: guaranteed town main infill, automatic filling, minimum effective volumes and the field errors that follow.

Fatih Selvi8 min
EN 12845

EN 12845 Sidewall Sprinklers

EN 12845 sidewall sprinkler layout: maximum coverage area, room width, number of rows, deflector position, K-factor selection and field errors.

Fatih Selvi8 min
EN 12845

EN 12845 Sprinkler Flow and K-Factor

EN 12845 K-factor notation (K57-K360), the SI formula Q = K root P, choosing K by hazard class, and the NFPA K conversion table.

Fatih Selvi8 min
EN 12845

EN 12845 Storage Configurations: ST1 to ST6

The EN 12845 ST1-ST6 storage configurations: block stacking, racking, mobile racking and drive-in, with the protection approach for each from field...

Fatih Selvi8 min
EN 12845

EN 12845 Subsidiary Dry and Alternate Extensions

EN 12845 subsidiary extensions: design limits for small dry or alternate branches fed from a wet system, sprinkler counts, water delivery time and...

Fatih Selvi8 min
EN 12845

EN 12845 Town Main as a Water Supply

EN 12845 conditions for using the town main as a sprinkler water supply: pressure-flow testing, the utility letter, EN 1717 backflow prevention and...

Fatih Selvi8 min
EN 12845

EN 12845 Underground and Above-Ground Pipework

EN 12845 pipework: underground and above-ground materials, burial depth, corrosion protection, thrust blocks and the field errors that follow.

Fatih Selvi8 min
EN 12845

EN 12845 Water Flow Alarm and Water Motor Gong

EN 12845 water motor alarms: the Pelton gong, pressure switches, retard chambers and the site installation errors, with an NFPA 13 comparison.

Fatih Selvi7 min
EN 12845

EN 12845 Water Spray Subsidiary Extensions

EN 12845 subsidiary water spray extensions on a sprinkler system: deluge valves, the 80 mm connection limit, transformer and turbine protection and...

Fatih Selvi8 min
EN 12845

EN 12845 Weekly User Routine

The EN 12845 weekly routine: pressure and level checks, water motor alarm test, automatic pump start test, diesel restart, trace heating and logboo...

Fatih Selvi8 min
EN 12845

EN 12845 Wet Pipe Installations

EN 12845 wet pipe sprinkler installations: permanently water-filled pipework, the 4 C lower limit, the LH/OH/HH default, alarm valve area limits an...

Fatih Selvi8 min
EN 12845

EN 12845 Zone Test and Drainage Facilities

EN 12845 zone test connection, alarm test valve, drainage arrangements, low-point drains, inspector test connection and correct drainage design on...

Fatih Selvi8 min
EN 12845

ESFR Design Criteria in Detail

ESFR design in detail: K-factor, pressure, design sprinklers, water demand, hydraulic calculation, ceiling conditions and commodity compatibility.

Fatih Selvi9 min
EN 12845

ESFR and CMSA Placement & Clearance Rules

ESFR and CMSA sprinkler placement: distance below ceiling, deflector position, sprinkler spacing and clear space above the top of storage.

Fatih Selvi7 min
EN 12845

HHS5–HHS12 High-Bay Sprinkler Design

Sprinkler design for high-bay warehouses with 5-12 m storage: choosing between ESFR and CMSA plus in-rack, water demand and typical solutions.

Fatih Selvi9 min
EN 12845

NFPA 13 vs EN 12845: A Detailed Comparison

A clause-by-clause comparison of NFPA 13 and EN 12845: units, density and area, K-factor notation, design method, water supply duration, hazard cla...

Fatih Selvi11 min
EN 12845

Obstructions to ESFR and CMSA Discharge

Obstruction rules for ESFR and CMSA: how beams, HVAC ducts, light fittings and rack supports affect the sprinkler discharge pattern.

Fatih Selvi8 min
EN 12845

Protecting Unheated Areas with ESFR and CMSA

ESFR and CMSA protection in unheated, freeze-prone warehouses: dry pipe valves, pre-action, antifreeze and cold-store sprinkler strategy.

Fatih Selvi8 min
EN 12845

Roof Slope, Skylight and Ventilation Limits

Roof slope, skylight and smoke-vent limits for ESFR and CMSA sprinkler systems, with standard values and alternative design strategies.

Fatih Selvi8 min