Cargo hold fires on container and general cargo ships are a serious risk — in the 2019 Maersk Honam incident the ship burned for a full month. NFPA 12 (Carbon Dioxide Extinguishing Systems) and SOLAS II-2 define fixed CO2 systems for cargo holds, engine rooms and pump rooms. The system discharges from a CO2 cylinder battery bank as total flooding. This article covers the backbone of shipboard CO2 design, concentration selection and the problems that arise by cargo type.

Total Flooding Concentrations

  • Cargo hold (other than vehicle spaces): 1 lb/30 ft³ (about 0.53 kg/m³) of gross volume; the initial discharge is based on the net volume given the cargo loaded, and more CO2 is released as needed (NFPA 12, 9.3.6.2)
  • Vehicle space (Ro-Ro): 34 percent of gross volume; 85 percent of it within 2 minutes where vehicles carry more than 19 L (5 gal) of fuel, two-thirds within 10 minutes for less fuel (NFPA 12, 9.3.6.3 and 9.3.6.4)
  • Machinery space: 34 percent of gross volume; 85 percent of it within 2 minutes (NFPA 12, 9.3.6.1)

CO2 Quantity Calculation

Mass-based calculation for a cargo hold of 5,000 m³ gross volume under NFPA 12 9.3.6.2:

  • Gross volume x 1 lb/30 ft³ (about 0.534 kg/m³)
  • 5,000 m³ × 0.534 kg/m³ ≈ 2,670 kg CO2
  • With 45 kg cylinders: 2,670 / 45 = 59.3, i.e. 60 cylinders
  • More CO2 is released as needed to keep the fire under control (NFPA 12, 9.3.6.2.2)

Battery Bank and Manifold

  • CO2 cylinder room: outside the protected space, in a fire-separated compartment
  • Manifold: cylinders connected in parallel through check valves
  • Pilot cylinder: for manual release and as backup
  • Alarm: 20-second delay for personnel evacuation
  • Pilot line: two release stations

Cargo-Type Challenges

  • Container: CO2 cannot penetrate the container; it only inerts the hold void space
  • Lithium battery container: CO2 does not stop thermal runaway — it only cuts oxygen while the reaction continues inside the battery
  • Dangerous goods (IMDG): Class 3 and 4.1 cargo must be stowed on a separate deck or in a separate hold
  • Hot hold: holds next to the engine room stay warmer, lowering the ignition threshold

2019 Maersk Honam Case

  • Indian Ocean, 7,700 TEU container ship
  • Calcium hypochlorite container — incorrect stowage
  • CO2 flooding was ineffective because the fire was inside the containers
  • 5 crew members died
  • Stowage rules were subsequently revised at IMO MSC 101

MEP Calc — 110+ Engineering Calculators

MEP Calc bundles 110+ engineering modules in one iOS app: 21 fire calculations (sprinkler, fire pump, clean agent) plus heating, cooling, HVAC, plumbing, steam and natural gas. Download it on the App Store.

Download MEP Calc on the App Store

SprinkCalc — Fire Sprinkler Design Across Three Standards

SprinkCalc covers hazard classification, design density and area, K-factor selection, water demand and hydraulic calculations for NFPA 13, FM Global and BS EN 12845 in a single iOS app, and exports a professional PDF report. One of the few tools that unifies all three major fire protection standards.

Download SprinkCalc on the App Store
Sources & Further Reading

NFPA 12, SOLAS II-2, IMO FSS Code Chapter 5, IMDG Code, USCG NVIC 9-97. NFPA 12 CO2 Extinguishing standard.